Miele Dishwasher Fault Codes |
|
F01 |
Water/heating NTC or leads short-circuited |
After this fault is registered, the heating will not be activated and rinse aid will
not be dispensed.
At the end of the program, the display shows Technical fault F01. The buzzer is activated for 2 minutes.
Cause:
NTC temperature sensor R30 or its connection leads short-circuited.
Remedy:
1. Check the temperature sensor and its leads for continuity. At 68°F (20°C), the
temperature sensor resistance should be approximately 14.9kΩ (± 750Ω); at
77°F (25°C), approximately 12kΩ (± 600Ω) (guide figures only).
2. Check the plug connections.
3. Replace the temperature sensor, if necessary. |
F02 |
Water/heating NTC or leads open-circuited |
 After this fault is registered, the heating will not be activated and rinse aid will
not be dispensed.
At the end of the program, the display shows
Technical fault F02. The buzzer is activated for 2 minutes.
Cause:
NTC temperature sensor R30 or its connection leads open-circuited.
Remedy:
1. Check the temperature sensor and its leads for continuity. At 68°F (20°C),
the temperature sensor resistance should be approximately 14.9kΩ
(± 750Ω); at 77°F (25°C), approximately 12kΩ (± 600Ω) (guide figures
only).
2. Check the plug connections.
3. Replace the temperature sensor, if necessary.; |
F11 |
Drainage fault |
Water present in appliance and is not being drained off. The display shows
Drain fault F11. The buzzer is activated for 2 minutes.
Background information:
After each drain pump step, the circulation pump operates for 2 seconds
and heater pressure switch B1/13 checks the water level. If it is too high
(large quantity of residual water remaining in the cabinet), the drainage time
is extended. If, after a further check, the water level is still too high, then the
program is interrupted, the fault code is saved and the drain pump is
activated.
Fault code F11 is also registered if heater relay 1K1 is not activated after the
fault code F51 register check; see Section 080-3.18. Drain hose kinked.
Remedy:
Check the drain hose for correct positioning.
Cause:
Drain blocked.
Remedy:
1. Clean the on-site drain.
2. Check the sump drain.
3. Check the filters.
4. Check the heater pressure switch and replace it if necessary.
Cause:
Ball in non-return valve in sump has not opened (e.g., jammed).
Remedy:
Clean the non-return valve in the sump or replace it if necessary.
Cause:
Foreign objects in the drain pump.
Remedy:
Clean the drain pump and its impeller.
Cause:
Drain pump defective.
Remedy:
1. Check the voltage supply to the drain pump.
2. If correct voltage is present, check the drain pump motor winding.
3. Replace the drain pump, if necessary.
Cause:
Foreign objects in heater pressure switch.
Remedy:
Check the heater pressure switch for blockages and correct switching point.
Cause:
Heater relay defective.
Heater relay (coil or contacts) becomes defective during the drainage step
(after fault code F51 register check).
Remedy:
Replace the heater relay. |
F12 |
Water intake fault at start of step |
During the first 5 seconds of any water intake step, at least 15 pulses from
flow meter B3/4 should be registered.
If this given number of pulses is not detected, the display shows the message
Water intake fault and the Status LED flashes. The water inlet valve will be
activated at 10-second intervals for one hour. The drain pump will also be
activated at intervals to prevent the possibility of the appliance overflowing.
All other components remain inactive. If these attempts to achieve the
minimum pulse rate fail, the buzzer is activated for 2 minutes.
Cause:
On-site shutoff valve (water supply) closed.
Remedy:
Open the shutoff valve.
Cause:
On-site water supply not in order.
Remedy:
The on-site water supply should be checked by a specialist.
Cause:
Flow meter B3/4 is not providing any pulses.
Remedy:
1. Check WaterProof System (WPS) valve Y2 (filter, restrictor disc).
2. Remove the left side panel.
3. Check that the plate with the reed switch on flow meter B3/4 is seated
correctly.
4. Check that the reed switch connection plug is seated correctly.
5. Replace the reed switch, if necessary.
6. Check the control lead from the electronic to flow meter B3/4.
7. Replace the water inlet mixer, if necessary.
Cause:
Water inlet valve defective.
Remedy:
Check the water inlet valve and replace it if necessary.
Cause:
Electrical connection open-circuited.
Remedy:
1. Check the wires to the flow meter reed switch for continuity.
2. Check the plug connections. |
F13 |
Water intake fault: Heater pressure switch |
he program is interrupted and the drain pump is operated. The display
shows the message Water intake fault F13. After approximately 2 to 4
minutes, the buzzer is activated for 2 minutes.
This fault is registered when the desired number of pulses, which varies
depending on program, has not been detected within a certain given time
(maximum 4 minutes).
If the selected program starts with a water softener flushing cycle, the fault
code register check is carried out earlier. In the event of a fault, the selected
program is interrupted after approximately 30 seconds and the fault is
indicated.
Cause:
On-site water supply not in order.
Remedy:
The on-site water supply should be checked by a specialist.
Cause:
Water inlet valve defective.
Remedy:
Check the water inlet valve and replace it if necessary.
Cause:
Flow meter B3/4 is providing too few pulses.
Remedy:
1. Check WPS valve Y2 (filter, restrictor disc).
2. Remove the left side panel.
3. Check that the plate with the reed switch on flow meter B3/4 is seated correctly.
4. Check that the reed switch connection plug is seated correctly.
5. Replace the reed switch, if necessary.
6. Check the control lead from the electronic to flow meter B3/4.
7. Replace the water inlet mixer, if necessary.
Cause:
Water flow pressure at on-site water supply is less than 14.5 pounds per
square inch (1 bar).
Remedy:
1. Check the water intake.
2. If voltage is present at the electronic for the solenoid valve, check the
solenoid valve Y2 leads for continuity.
3. Check the filter at WPS valve Y2.
Cause:
Filter in WPS clogged.
Remedy:
1. Disconnect the machine from the power supply.
2. Close the on-site water supply.
3. Unscrew the WPS from the on-site water supply.
4. Remove the washer from the threaded union.
5. Remove the filter with needlenose pliers.
6. Clean or replace the filter as necessary. |
F14 |
Water intake fault: Heater pressure switch |
The program is interrupted and the drain pump is operated. The display
shows the message Technical fault code F14 - Call Service Dept. The
buzzer is activated for 2 minutes.
With the circulation pump operating after a water intake step, the heater
pressure switch is checked to ensure that sufficient water pressure exists in
the wash water circuit. For this the heater relay must have been activated.
Cause:
Heater pressure switch B1/13 defective.
Remedy:
1. Check the heater pressure switch.
2. Check the connection plug and wiring harness.
3. Replace the heater pressure switch, if necessary.
Cause:
Circulation pump inoperative. Circulation pressure too low (no pressure at
heater pressure switch). Pump may be blocked by foreign objects.
Remedy:
1. Check the circulation pump for foreign objects.
2. Check the circulation pump capacitor.
3. Replace the circulation pump, if necessary.
Cause:
Foreign objects in heater pressure switch.
Remedy:
Replace the heater pressure switch.
Cause:
Flow meter B3/4 defective (incorrect water quantity registered).
Remedy:
1. Check that the plate with the reed switch on flow meter B3/4 is seated
correctly.
2. Check that the reed switch connection plug is seated correctly.
3. Replace the reed switch, if necessary.
4. Check the control lead from the electronic to flow meter B3/4.
5. Remove the water inlet mixer and replace if necessary.
Cause:
Circulation pump defective.
Remedy:
1. Check the circulation pump power supply.
2. Check the circulation pump capacitor.
3. Replace the circulation pump.
Cause:
Circulation pump winding overheated; winding protection has cut out.
Remedy:
Replace the circulation pump.
Cause:
After a water intake step, heater pressure switch B1/13 has not opened
switching steps 11–12 and 21–22. This starts the anti-stiction routine.
Remedy:
Replace the heater pressure switch.
Cause:
Motor capacitor defective.
Remedy:
Check the motor capacitor and replace it if necessary.
Cause:
Contacts on heater pressure switch B1/13 short-circuited.
Contamination on the plug of the heater wiring harness and a conductive
connection between the plugs and the main harness causes a short circuit to
the contacts.
Remedy:
1. Replace the heater wiring harness.
2. Replace heater pressure switch B1/13.
3. Reconnect the two individual plugs from the main harness (AMP 6.3 x 0.8)
and apply new insulation sleeves. Do not interchange the plugs. |
F15 |
Water intake fault: Hot water |
|
F18 |
Flow meter stationary state monitor B3/4 |
The program is interrupted and the drain pump is operated. The display
shows the message Technical fault code F18 - Call Service Dept. The
buzzer is activated for 2 minutes.
The water inlet valve is open when it should not be (a signal to open it has
not been given by the electronic). Water then flows into the appliance and
unexpected pulses from flow meter B3/4 are detected. Unexpected pulses
from flow meter B3/4 are also detected when the water inlet valve is not
activated.
Cause:
Water inlet valve defective.
Remedy:
Check the water inlet valve and replace it if necessary.
Cause:
Interference pulses.
Remedy:
Replace the water inlet mixer. |
F19 |
Flow meter B3/4 stiff and not turning freely |
The program is interrupted and the drain pump is operated. The display
shows Technical fault F19. Call the Service Department. The buzzer
is activated for 2 minutes. Background information: Satisfactory test routines to monitor free rotation
of the flow meter impeller could not be established. Technical Information
37
G 1202
Wash block water intake start:
a Measuring time for 0.26 gallons (one liter)
1 Normal water intake time sufficient (1 minute in this example)
2 Extended water intake time required (2 minutes in this example).
3 After 0.26 gallons (one liter) intake, it is clear that neither the normal nor
the extended water intake time will be sufficient. Therefore, the test routine
is started.
Test routine:
a Measuring time for 0.26 gallons (one liter)
b Test routine successful; water intake time is extended.
c Test routine unsuccessful; fault code F19 is registered.
a. During the first step, water intake solenoid Y2 is activated in order to let
another 0.52 gallons (2 liters) flow into the machine. The required time is
calculated on the basis of the time that the 0.26 gallons of water already
in the machine required for intake.
Note: The volume of water cannot cause the machine to overflow, even if
the flow meter is inaccurate.
Circulation pump M6 is now activated for 2 minutes in order to wet the
dishes in the dishwasher and to fill any spaces with water. Drain pump
M8 is then activated for one minute. This creates a measurement basis
for the actual test.
During the test, water inlet valve Y2 is activated until a defined number
of pulses corresponding to a water volume of approximately 0.37 gallons
(1.4 liters) is reached. Circulation pump M6 is then activated once more.
b. The program continues to run without interruption. The maximum water
intake time is extended to 4 minutes. This time value is saved by the
electronic for future water intake. For future water intakes, if the time
needed for 0.26 gallons to flow into the machine differs by 15 percent, a
new test routine flow will be started.
c. If heater pressure switch B1/13 is activated, the program is interrupted
immediately, the drain pump is operated, and fault F19 is registered.
Cause:
Flow meter defective.
Remedy:
Replace the water inlet mixer. |
F24 |
Heater relay contact |
The program is interrupted and the drain pump is operated. The display
shows Technical fault F24. Call the Service Department. The buzzer is
activated for 2 minutes.
Background information:
When the circulation pump is not operating, the heater relay contacts are
checked. If supply voltage is then applied to the electronic’s inputs, the fault is
registered.
Cause:
Heater relay contacts have fused together.
Remedy:
Replace the heater relay.
Cause:
Moisture in heater relay.
Remedy:
Replace the heater relay.
Cause:
Fault in the plug on the exit side of the heater relay.
Contamination on the plug of the heater wiring harness causes resistance
values between the contact blades to fall below 10 megaohms (10MΩ).
Remedy:
1. Disconnect the appliance from the power supply.
2. Disconnect plug 5 from the electronic.
3. Measure the resistance between the lines of the electronic for heater
pressure switch B1/13 (pins 12 and 22 on plug 5).
4. If the measured resistance value is smaller than 10 megaohms (10MΩ),
then the heater wiring harness must be replaced. |
F25 |
Desired temperature fault |
At the end of the wash program, the display shows the message Technical
fault code F25 - Call Service Dept. The Status LED flashes. The buzzer is
activated for 2 minutes.
During the heating stage, the desired temperature has not been reached within
the given time (minimum 75 minutes). In subsequent wash blocks, after this
fault has registered, the heating is not activated and no rinse aid is dispensed.
Cause:
Heater defective.
Remedy:
Replace the heater.
Cause:
Heater relay defective.
Remedy:
1. Check the heater relay solenoid.
2. Check the heater relay solenoid voltage (12VDC) from the electronic.
3. Replace the electronic, if necessary.
Cause:
Excess quantity of detergent or rinse aid dispensed. Excess foam has developed.
Remedy:
Check the dispensed quantities of detergent and rinse aid. Follow the
information given in the operating instructions. |
F26 |
Boiling protection |
The program is interrupted and the drain pump is operated. The display
shows Technical fault F26. Call the Service Department. The buzzer is
activated for 2 minutes.
Cause:
Temperature at NTC temperature sensor has exceeded 194°F (90°C).
Remedy:
Check the heater relay and replace it if necessary.
Cause:
NTC temperature sensor providing inaccurate information.
Remedy:
Replace the NTC temperature sensor.
Cause:
Heater relay closed.
Remedy:
Replace the heater relay. |
F40 |
Electronic fault |
The program is interrupted and the drain pump is operated. The display
shows Technical fault F40. Call the Service Department. The buzzer is
activated for 2 minutes.
Cause:
The electronic has a fault that cannot be repaired by the service department
(such as a hardware fault).
Remedy:
Replace the electronic. |
F42 |
Line frequency registration fault |
The program is interrupted and the drain pump is operated. The display
shows Technical fault F42. Call the Service Department. The buzzer is
activated for 2 minutes.
A check is carried out to ensure that the line frequency is within certain valid
ranges (50 ± 5 Hz or 60 ± 5 Hz). This fault is registered when it cannot clearly
be established which valid range is applicable.
Cause:
Main power supply not in order.
Remedy:
The main power supply should be checked by a specialist. |
F47 |
Mains frequency registration fault |
|
F51 |
Heater pressure switch |
The program is interrupted and the drain pump is operated. The display
shows Technical fault F51. Call Service Department. The buzzer is
activated for 2 minutes.
Background information:
Start position:
One second after the program start, heater relay K1/1 is activated. This
enables a check as to whether the contacts on heater pressure switch B1/13
have closed on switching steps 21/22 or 11/12.
Cause:
Heater relay defective; contact open.
Remedy:
Replace the heater relay.
Cause:
Heater relay solenoid defective.
Remedy:
Replace the heater relay.
Cause:
Connection from heater relay to electronic module open-circuited.
Remedy:
1. Check plug connections.
2. Check the connection wires for continuity.
Cause:
Heater pressure switch open- or short-circuited.
Remedy:
Replace the heater pressure switch.
Cause:
Connection from heater pressure switch to electronic open-circuited.
Remedy:
1. Check plug connections.
2. Check the connection wires for continuity.
Cause:
Foreign objects in heater pressure switch.
Remedy:
Replace the heater pressure switch. |
F52 |
Heater pressure switch has reset during heating |
The program continues from the wash block in which the fault is registered
without the heating being activated.
The fault will only be indicated when the fault code memory is checked in the
service mode.
Cause:
Excess quantity of detergent or rinse aid dispensed. Excess foam has
developed.
Remedy:
Check the dispensed quantities of detergent and rinse aid. Follow the
information given in the operating instructions.
Note:
A check should also be made to ensure that the type of detergent used
matches the setting. When, for example, combination products (2-in-1 or
3-in-1 tablets) are used but the corresponding parameter has been set to Normal, rinse aid will be dispensed twice.
Cause:
Heater pressure switch defective.
Remedy:
Replace the heater pressure switch.
Cause:
Pump pressure too low.
Remedy:
Clean the circulation pump and remove any foreign objects that may be
present.
Cause:
An item has tipped over and a large quantity of water is retained, e.g., in a
bowl, and is then not available for the wash water circuit. This reduces the
pump pressure.
Remedy:
Follow the loading information given in the operating instructions. |
F53 |
Speed sensor fault |
|
F63 |
Slide shutter fault |
|
F67 |
Circulation pump speed to slow |
|
F68 |
Circulation pump operation after switch off |
|
F69 |
Circulation pump blocked |
The program is interrupted and the drain pump is operated. The fault will be
indicated in the display or via LEDs. The buzzer is activated for 2 minutes.
With the circulation pump operating, the heater pressure switch contacts are
checked. For this, the heater relay must have been activated and both
electronic’s inputs must be potential-free.
Cause:
Heater pressure switch defective.
Remedy:
Replace the heater pressure switch.
Cause:
Circulation pressure too low; circulation pump is blocked by foreign objects.
Remedy:
Clean the circulation pump and remove any foreign objects that may be
present. |
F70 |
Float switch fault |
After the WaterProof System has activated, the program is interrupted and
the drain pump is operated. The fault will be indicated in the display or via
LEDs. The buzzer is activated for as long as the fault is detected.
Note: The drain pump continues to operate even after the appliance has
been shut off. The drain pump can only be deactivated by disconnecting the
power supply connection.
Cause:
Water in the drip pan. Changeover contact of overflow float switch B8/3
closed from 1 to 4 (refer to the wiring diagram).
Remedy:
1. Remove the water from the drip pan (e.g., with an absorbent cloth).
Note:
Upon opening the appliance and removing all water, there should be no
smudges, smears or traces of deposits. Take pictures of any deposits, if
possible, and note their type (rust, calcium, detergent, or salt?).
2. Check all hoses, connections and threaded unions for leaks.
Note:
If the leak source has not yet been detected, check the following areas
in the toekick and the drip pan for wear and tear:
Connection between the circulation pump and the sump
Axial face seal of the circulation pump
Connection between the drain pump and the sump
Connection between the salt container and the water intake
Connection between the water intake and the cabinet side wall
Overflow (e.g., excess foam formation)
Water level between the overflows ( seating of the lower door seal?)
Connection between the cabinet and the salt container
Non-return valve in the sump ( water running back from the drain hose?)
3. Check overflow float switch B8/3 for continuity and correct operation.
4. Carefully dry all electrical components in the drip pan area.
Cause:
Float switch defective.
Remedy:
Replace overflow float switch B8/3.
Cause:
Drip pan warped after transport.
Remedy:
1. Remove the drip pan.
2. Bend the drip pan straight or replace it if necessary. |
F84 |
Slide shutter positioning fault |
|
F85 |
Slide shutter signal change fault |
|
F86 |
Salt container lid contact fault |
|
F87 |
Sensor softener fault |
|
F88 |
Turbidity sensor fault |
If this fault is registered, the program is not interrupted. The fault will only be
indicated when the fault memory is checked in the service mode.
If this fault is registered, the program continues with default settings.
Cause:
False or no values from turbidity sensor.
Remedy:
1. Check the turbidity sensor for correct function.
2. Replace the spray arm feed pipe with turbidity sensor, if necessary.
Cause:
Foreign objects in the measurement path.
Remedy:
Check the feed pipe and replace it if necessary.
Cause:
Turbidity sensor connection wires open-circuited.
Remedy:
Check the connection wires for continuity. |
F91 |
Load size registration inactive |
|